Dye Penetrant Test
Every plate that WCR services is dye penetrant tested. This will eliminate any plates that may have pinholes, cracks or anything that would cause cross contamination. It is extremely important that every plate is dye tested as 90% of the plates tested have less than 10% failure rate This means that if the plates are random checked or tested at a 10% rate the bad plates will not be identified. Pin holes or cracks can be very costly if put back into operation. It could mean costly down-time and possibly loss of product if cross contamination would occur.
 